簡要描述:高靈敏度毫米波功率計Features
0.01-220 GHz operating frequency
High sensitivity
Up to 55 dB dynamic range (0.1uW-30mW)
Small measuring time (< 1 sec)
RS-232, GPIB interface
SCPI protocol

  • 產(chǎn)品型號:Mm-Wave power meter
  • 更新時間:2025-03-12
  • 訪  問  量:956

產(chǎn)品簡介

品牌其他品牌產(chǎn)地類別進口
應(yīng)用領(lǐng)域農(nóng)林牧漁,電子/電池,汽車及零部件,電氣

詳細介紹

 

高靈敏度毫米波功率計Features  
  • 0.01-220 GHz operating frequency

  • High sensitivity

  • Up to 55 dB dynamic range (0.1uW-30mW)

  • Small measuring time (< 1 sec)

  • RS-232, GPIB interface

  • SCPI protocol

高靈敏度毫米波功率計Applications  
  • Recommended for use by Rohde & Schwarz

  • Measurements of power level of mm-wave signal

  • Test equipment

Description

The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.

DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor.

Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research.

ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay.

Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse.

Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available.

Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels.

Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors.  Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time.

 

DPM-XX Key Features and Specifications

- Display readings: milliWatts, microWatts or dBm

- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)

- Frequency Range: 10 MHz to 220 GHz

- Min. measured Power: 0.1 microWatt (depending on frequency band)

- Dynamic Measurement Range: 55dB max. (depending on frequency band)

- Frequency step: 10 MHz

- SCPI or ELVA’s command protocol

- RS-232, GPIB interface

- Calibration accuracy ±0.04 dB (log) or ±1%

- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory

- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness.

Model Number DPM-C DPM -28 DPM -22 DPM -19 DPM -15 DPM -12 DPM -10 DPM -08 DPM -06 DPM -05
Frequency Band Ka Q U V E W F D G
Frequency Range, GHz 0.01-26.5 14757 33-50 40-60 50-75 60-90 75-110 90-140 110-170 140-220
Input Waveguide/Impedance 50 Ohm, Coaxial WR-28 WR-22 WR-19 WR-15 WR-12 WR-10 WR-08 WR-06 WR-05
Wavequide Flange/Connector SMA, male UG-599/U UG-383/U UG-383/U-M UG-385/U UG-387/U UG-387/U-M UG-387/U-M UG-387/U-M UG-387/U-M
Dynamic Range, dB (max) 50 55 55 55 55 55 55 55 50 40
Min Measured Power Level, dBm -33 -43 -43 -43 -43 -43 -40 -40 -35 -25
Measurement Rate (default), times per sec 2 2 2 2 2 2 2 2 2 2
VSWR (power sensor) 1.2:1 1.3:1 1.3:1 1.3:1 1.3:1 1.4:1 1.4:1 1.4:1 1.4:1 1.4:1

Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).

 

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

全國統(tǒng)一服務(wù)電話

021-62209657

電子郵箱:sales@eachwave.com

公司地址:上海市閔行區(qū)劍川路955號707-709室

業(yè)務(wù)咨詢微信

欧美亚洲另类图片与小说| 久久97成人欧美日韩网站| 久久亚洲精品无码观看不| 在线观看扣喷水| 999久久网站国产毛片| 蜜臀avove一区二区| 在线精品亚?第一区焦香| 尤物yw午夜国产精品视频| 久久三级片视频| 天天干天天操天天干天天| 国内精品一区二区三区av| 国产羞羞视频在线观看播放| 亚洲黄色在线| 亚洲成电影在线观看青青| 色综合久久久久| 国产精品自在线拍国产| 2023久久久| 精品国产乱子伦一区二区三区 | 秋霞久久久久久一区二区| 欧美日韩无线码在线观看| 91精品国产91青青碰| 亚洲日韩欧美综合热小说| 一二三区中文字幕在线观看| 粉嫩国产精品一区二区久久| 久久久国产精品午夜一区| 日本大片在线一区二区三区| 亚洲gv钙片在线观看网站| 97 在线免费观看视频| 色婷婷亚洲精品天天综合影院| 亚洲av精品久久久久a| 日韩av中午字幕在线观看| 亚洲欧洲久久激情久av| 亚洲青娱乐天堂在线观看| 大香蕉亚洲视频在线观看| 欧美大片日韩精品www| 国产亚洲精品美女久久久久久| 亚洲国产97在线精品一区| 一级在线电影免费播放看| 久久久国产精华液2023| 水蜜桃久久夜色精品黑人| 成人无码区免费视频网站|